Result: Pleural Effusion Measurement Method on Thoracic Image of Dengue Fever Patient Using Image Processing Technique.
Further information
Pleural effusion is the accumulation of fluid in the pleural cavity. The pleural cavity is located between the pleural layer that covers the lungs and the pleural layer that attaches to the inner wall of the chest cavity. This condition generally occurs due to complications of the disease, including Dengue Hemorrhagic Fever (DHF). Information about the severity of DHF suffered by patients is very important to determine therapy and patient observation because improper handling can lead to patient death. Pleural Efusion Index (PEI) is an indicator used to determine the severity of DHF. So far, doctors or radiologists have measured PEI using conventional chest X-rays manually with a ruler. This method is complicated and time-consuming and must be performed by a specialist such as a doctor or radiologist. Meanwhile, doctors or radiologists who can measure PEI are not available all the time. Therefore, an automatic, fast, and accurate system is needed that can measure PEI and is practical for everyone so that DHF treatment can be carried out quickly. In this study, we developed a PEI measurement method automatically using image processing techniques using digital chest images. We implemented this method on a small Raspberry Pi computer so it can become a portable system. With this portable system, a doctor or radiologist can find out the PEI value and at the same time see the patient's condition directly at the treatment site. This system can also measure PEI directly from conventional film images using an attached camera. The design of the computer program includes preprocessing stages, determining the width of the hemithorax, segmentation, and finally measuring the PEI. The material used in this study was 20 chest images of DHF patients suffering from pleural effusion. The correlation between measurements using this system and manual measurements produces a value of 0.70 which means a high correlation. [ABSTRACT FROM AUTHOR]
Copyright of Mathematical Modelling of Engineering Problems is the property of International Information & Engineering Technology Association (IIETA) and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)